Red-Hat II
Optional Electrical Features
ASCO
Red-Hat valves are available with a wide variety of optional coil and
solenoid features. Most of these options can be included in solenoid
valves that are approved by UL, FM and CSA.
The options you desire should be
identified by the use of catalog number prefixes keyed to the coil for
the valve you are specifying.
To identify the proper prefix, use
the valve Series Specification Table (see specific valve you are
interested in) to determine the Watt Rating/Class of Coil Insulation
for the valve you are ordering.
Using the "Solenoid Options
for Red-Hat II Valves" table, find the desired solenoid option in
the left column and the Watt Rating/Class of Coil Insulation in the
next column. The choice of prefixes is shown in the next two columns
on that horizontal line. The first column indicates the prefix to use
if Class F temperature protection is sufficient for your requirements.
The second column provides the desired solenoid option plus the higher
temperature protection of a Class H coil.
|
|
For
example, to select an 8262G2 valve with a Class H Open Frame Spade
Terminal Solenoid, assuming the voltage to be 120 volts, AC, 60 Hz:
- In the Specification Table for
Series 8262, the Watt Rating/Class of Coil Insulation is 6.1/F for
Catalog Number 8262G2.
- Using the Solenoid Options for
Red-Hat II Valves table, find the listing for "Open Frame
Solenoid with Spade Terminal Coil" in the left column. Then
find 6.1/F under AC coils in the next column. Reading horizontally
across to the column headed "Class H Coil," you'll find
the prefix "OFST." To order, specify Catalog No.
OFST8262G2, 120/60. (Note: Always include the voltage and
frequency.)
|
| Solenoid
Options for Red-Hat II Valves |
Solenoid
Options
Required |
Watt
Rating/
Class of Coil
Insulation |
Class
F
Coil Prefix |
Class
H
Coil Prefix |
| AC |
DC |
General
Purpose
Solenoid
(Standard Valve
Construction) |
6.1/F
10.1/F |
10.6/F
11.6/F |
-- |
HT |
9.1/F
17.1/F |
22.6/F |
-- |
HB |
Panel
Mount
Type 1 General
Purpose
Solenoid |
6.1/F
10.1/F |
10.6/F
11.6/F |
GP |
GPHT |
9.1/F
17.1/F |
22.6/F |
GP |
GPHB |
Type
7
Explosionproof
Solenoid |
6.1/F
10.1/F |
10.6/F
11.6/F |
EF |
EFHT |
9.1/F
17.1/F |
22.6/F |
EF |
EFHB |
10.1/F
15.1/F
17.1/F |
1.4/F
11.6/F |
EV |
-- |
Open
Frame
Solenoid with
Spade Terminal
Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
OFSF |
OFST |
9.1/F
17.1/F |
22.6/F |
OFSP |
OFSS |
Panel
Mount
Solenoid with
Spade Terminal
Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
OPSF |
OPST |
9.1/F
17.1/F |
22.6/F |
OPSP |
OPSS |
Open
Frame
Solenoid with
Screw Terminal
Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
OFKF |
OFKH |
9.1/F
17.1/F |
22.6/F |
OFKP |
OFKB |
Panel
Mount
Solenoid with
Screw Terminal
Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
OPKF |
OPKH |
9.1/F
17.1/F |
22.6/F |
OPKP |
OPKH |
Junction
Box
with Spade
Terminal Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
JSF |
JST |
9.1/F
17.1/F |
22.6/F |
JSP |
JSS |
Panel
Mount
Junction Box
with Spade
Terminal Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
JPSF |
JPST |
9.1/F
17.1/F |
22.6/F |
JPSP |
JPSS |
Junction
Box
with Screw
Terminal Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
JKF |
JKH |
9.1/F
17.1/F |
22.6/F |
JKP |
JKB |
Panel
Mount
Junction Box
with Screw
Terminal Coil |
6.1/F
10.1/F |
10.6/F
11.6/F |
JPKF |
JPKH |
9.1/F
17.1/F |
22.6/F |
JPKP |
JPKB |
DIN
Connection
Solenoid |
6.1/F
10.1/F |
10.6/F
11.6/F |
SC |
SU |
9.1/F
17.1/F |
22.6/F |
SD |
SV |
Panel
Mount
DIN Connection
Solenoid |
6.1/F
10.1/F |
10.6/F
11.6/F |
OPSC |
OPSU |
9.1/F
17.1/F |
22.6/F |
OPSD |
OPSV |
Important Note: One-piece molded
epoxy Red-Hat II solenoids are a unique combination of coil and enclosure.
When ordering some Red-Hat II options, it may be necessary to specify the
appropriate catalog number prefixes for both the enclosure and the coil.
Type
1 General Purpose Solenoids with Class F High Temperature Coils
Enclosures:
- Also meet Type 2 Dripproof, Types 3 and 3S Raintight, and Types
4 and 4X Watertight requirements
- Supplied standard with ½ threaded conduit hub and built-in
strain relief for leads
Coils:
- Insulation System suitable for coil temperatures up to 155°C.²
For ambient temperature requirements, refer to specific Series and
charts in Engineering Section.
- Suitable for both 50 and 60 Hz ¹
Ordering Information: Supplied
standard on all Red-Hat II Valves.
|
|
Type
1 General Purpose Solenoids with Class H High Temperature Coils
Enclosures:
- Also meet Type 2 Dripproof, Types 3 and 3S Raintight, and Types
4 and 4X Watertight requirements
- Supplied standard with ½ threaded conduit hub and built-in
strain relief for leads
Coils:
- Insulation System suitable for coil temperatures up to 180°C.²
For ambient temperature requirements, refer to specific Series and
charts in Engineering Section.
- Suitable for both 50 and 60 Hz ¹
Ordering Information: Depending on
wattage, use catalog number prefix "HT" or "HB"
(e.g. HT8210G2) and specify voltage.
|
Panel
Mount Type 1 General Purpose Solenoids with Class F or Class H High
Temperature Coils
Enclosures:
- Panel mountable
- Also meet Type 2 Drip proof, Types 3 and 3S Rain tight, and
Types 4 and 4X Watertight requirements
- Supplied standard with ½ threaded conduit hub and built-in
strain relief for leads
Coils:
- Same as Class F or Class H above
Ordering Information: For Class F
coil, use catalog number prefix "GP" (e.g., GP8210G2) and
specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"GPHT" or "GPHB" (e.g., GPHT8210G2) and specify
voltage.
|
|
Type
7 (A, B, C and D) Explosion proof Solenoids with Class F High
Temperature Coils
Enclosures:
- Also meet Types 3 and 3S Raintight, Types 4 and 4X Watertight,
types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition
proof requirements. Refer to Engineering
Section.
- Supplied standard with ½ threaded conduit hub and built-in
strain relief for leads
Coils:
- Insulation System suitable for coil temperatures up to 155°C.²
For ambient temperature requirements, refer to specific Series and
charts in Engineering Section.
- Suitable for both 50 and 60 Hz ¹
Ordering Information: Use catalog
number prefix "EF" (e.g. EF8210G2) and specify voltage.
|
Type
7 (A, B, C and D) Explosion proof Solenoids with Class H High
Temperature Coils
Enclosures:
- Also meet Types 3 and 3S Rain tight, Types 4 and 4X Watertight,
types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition
proof requirements. Refer to Engineering
Section.
- Supplied standard with ½ threaded conduit hub and built-in
strain relief for leads
Coils:
- Insulation System suitable for coil temperatures up to 180°C.²
For ambient temperature requirements, refer to specific Series and
charts in Engineering Section.
- Suitable for both 50 and 60 Hz ¹
Ordering Information: Depending on
wattage, use catalog number prefix "EFHT" or "EFHB"
(e.g., EFHT8210G2) and specify voltage. |
|
Type
7 (A, B, C and D) Explosion proof Solenoids with Class F Coil only
Enclosures:
- Also meet Types 3 and 3S Rain tight, Types 4 and 4X Watertight,
types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition
proof requirements. Refer to Engineering
Section.
- Supplied with ½ 316 stainless steel threaded conduit hub,
stainless steel base plate, and built-in strain relief for leads
Coils:
- Insulation System suitable for coil temperatures up to 155°C.²
For ambient temperature requirements, refer to specific Series and
charts in Engineering Section.
- Suitable for both 50 and 60 Hz ¹
Ordering Information: Use catalog
number prefix "EV" (e.g. EV8210G2) and specify voltage.
Note: Not offered in any other class of insulation. |
Open
Frame Solenoids with Class F or Class H High Temperature Spade
Terminal Coils
Valves with open frame solenoid construction are intended for use when
a solenoid enclosure is not needed, e.g., mounting in a control
cabinet.
Coils:
- Insulation System suitable for coil temperatures up to 155°C²
(for Class F) or up to 180°C² (for Class H) For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- ¼" spade terminals
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F
coil, depending on wattage, use catalog number prefix "OFSF"
or "OFSP" (e.g., OFSF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"OFSS" or "OFST" (e.g., OFST8210G2) and specify
voltage.
Note: Spade Terminal Coils are not available above 250 volts, AC or
DC. |
|
Panel
Mount Solenoids with Class F or Class H High Temperature Spade
Terminal Coils
Coils:
- Insulation System suitable for coil temperatures up to 155°C²
(for Class F) or up to 180°C² (for Class H) For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- Panel mountable with ¼" spade terminals
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F
coil, depending on wattage, use catalog number prefix "OPSF"
or "OPSP" (e.g., OPSF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"OPSS" or "OPST" (e.g., OPST8210G2) and specify
voltage.
Note: Spade Terminal Coils are not available above 250 volts, AC or
DC. |
Open
Frame Solenoids with Class F or Class H High Temperature Screw
Terminal Coils
Valves with open frame solenoid construction are intended for use when
a solenoid enclosure is not needed, e.g., mounting in a control
cabinet.
Coils:
- Insulation System suitable for coil temperatures up to 155°C²
(for Class F) or up to 180°C² (for Class H) For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- #8 screw terminals
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F
coil, depending on wattage, use catalog number prefix "OFKF"
or "OFSKP" (e.g., OFKF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"OFKH" or "OFKB" (e.g., OFKH8210G2) and specify
voltage.
|
|
Panel
Mount Solenoids with Class F or Class H High Temperature Screw
Terminal Coils
Coils:
- Insulation System suitable for coil temperatures up to 155°C²
(for Class F) or up to 180°C² (for Class H) For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- Panel mountable with #8 screw terminals
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F
coil, depending on wattage, use catalog number prefix "OPKF"
or "OPKP" (e.g., OPKF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"OPKB" or "OPKH" (e.g., OPKH8210G2) and specify
voltage.
|
Junction
Box Solenoids with Class F or Class H High Temperature Spade or Screw
Terminal Coils
Enclosures:
- Meet Type 1 General Purpose, Type 2 Dripp roof, Types 3 and 3S
Rain tight, and Types 4 and 4X Watertight requirements
- Supplied standard with ½ threaded conduit hub and grounding
provision
Coils:
- Insulation System suitable for coil temperatures up to 155°C²
(for Class F) or up to 180°C² (for Class H) For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- Must be ordered with either: #8 screw terminals or ¼"
spade terminals
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F
coil, depending on wattage, use catalog number prefix "JSF",
"JSP", "JKF" or "JKB" (e.g., JSF8210G2)
and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"JSS", "JST", "JKH" or "JKB"
(e.g., JKH8210G2) and specify voltage.
|
|
Junction
Box Solenoids for Class F or Class H Coils
Junction Box (shown installed on Red-Hat II solenoid) is a zinc coated
steel housing with two 7/8" knockouts for
through wiring. UL listed when ordered factory assembled. Also
available, without UL listing, as a kit with grounding screw for field
installation.
Ordering Information: For factory
assembly, add prefix "JB" to Valve Catalog Number (e.g.,
JB8210G2).
For kit, use number 272140. |
Class
F or Class H High Temperature Coils with DIN Connections
- Meet ISO 4400/DIN 43650
requirements
- Class F insulation system
suitable for coil temperatures up to 155°C.² For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- Class H insulation system
suitable for coil temperatures up to 180°C.² For ambient
temperature requirements, refer to specific Series and charts in Engineering
Section.
- "Enclosure protection"
with DIN connector equivalent of Types 1 and 4
- Suitable for both 50 and 60 Hz ¹
Ordering Information: For
Class F coil, depending on wattage, use catalog number prefix
"SC" or "SD" (e.g., SC8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix
"SU" or "SV" (e.g., SU8210G2) and specify voltage.
Note: Optional DIN-type strain-relief connector kit includes a gasket
and mounting screw. Outlet accommodates cable with O.D. of 0.310"
to 0.400". Must be ordered seperately as Kit No. 236034 |
|
|
Notes:
¹ Can be suplied for 50 Hz at a reduced voltage which is standard throughout
the world, i.e., 120/60, 110/50.
² UL Limitations are 140°C for Class F insulation systems and 160°C for
Class H insulation systems.
|
|
Credit Cards Accepted by PSI
 |
 |
|
.
|
|
 |
 |
 |
 |
|