ASCO is the worldwide leader in the design and manufacture of quality solenoid valves.  ASCO products are designed to control the flow of air, gas, water, oil, steam. Please let us address your applications.

Asco (877)-274-2763
toll free - 24 Hours a Day
asco home products about us contact us links safety

Asco
Red-Hat II
Optional Electrical Features
      ASCO Red-Hat valves are available with a wide variety of optional coil and solenoid features. Most of these options can be included in solenoid valves that are approved by UL, FM and CSA.
      The options you desire should be identified by the use of catalog number prefixes keyed to the coil for the valve you are specifying.
      To identify the proper prefix, use the valve Series Specification Table (see specific valve you are interested in) to determine the Watt Rating/Class of Coil Insulation for the valve you are ordering.
      Using the "Solenoid Options for Red-Hat II Valves" table, find the desired solenoid option in the left column and the Watt Rating/Class of Coil Insulation in the next column. The choice of prefixes is shown in the next two columns on that horizontal line. The first column indicates the prefix to use if Class F temperature protection is sufficient for your requirements. The second column provides the desired solenoid option plus the higher temperature protection of a Class H coil.
        For example, to select an 8262G2 valve with a Class H Open Frame Spade Terminal Solenoid, assuming the voltage to be 120 volts, AC, 60 Hz:
  1. In the Specification Table for Series 8262, the Watt Rating/Class of Coil Insulation is 6.1/F for Catalog Number 8262G2.
  2. Using the Solenoid Options for Red-Hat II Valves table, find the listing for "Open Frame Solenoid with Spade Terminal Coil" in the left column. Then find 6.1/F under AC coils in the next column. Reading horizontally across to the column headed "Class H Coil," you'll find the prefix "OFST." To order, specify Catalog No. OFST8262G2, 120/60. (Note: Always include the voltage and frequency.)

Solenoid Options for Red-Hat II Valves
Solenoid Options
Required
Watt Rating/
Class of Coil
Insulation
Class F
Coil Prefix
Class H
Coil Prefix
AC DC
General Purpose
Solenoid
(Standard Valve
Construction)
6.1/F
10.1/F
10.6/F
11.6/F
-- HT
9.1/F
17.1/F
22.6/F -- HB
Panel Mount
Type 1 General
Purpose
Solenoid
6.1/F
10.1/F
10.6/F
11.6/F
GP GPHT
9.1/F
17.1/F
22.6/F GP GPHB
Type 7
Explosionproof
Solenoid
6.1/F
10.1/F
10.6/F
11.6/F
EF EFHT
9.1/F
17.1/F
22.6/F EF EFHB
10.1/F
15.1/F
17.1/F
1.4/F
11.6/F
EV --
Open Frame
Solenoid with
Spade Terminal
Coil
6.1/F
10.1/F
10.6/F
11.6/F
OFSF OFST
9.1/F
17.1/F
22.6/F OFSP OFSS
Panel Mount
Solenoid with
Spade Terminal
Coil
6.1/F
10.1/F
10.6/F
11.6/F
OPSF OPST
9.1/F
17.1/F
22.6/F OPSP OPSS
Open Frame
Solenoid with
Screw Terminal
Coil
6.1/F
10.1/F
10.6/F
11.6/F
OFKF OFKH
9.1/F
17.1/F
22.6/F OFKP OFKB
Panel Mount
Solenoid with
Screw Terminal
Coil
6.1/F
10.1/F
10.6/F
11.6/F
OPKF OPKH
9.1/F
17.1/F
22.6/F OPKP OPKH
Junction Box
with Spade
Terminal Coil
6.1/F
10.1/F
10.6/F
11.6/F
JSF JST
9.1/F
17.1/F
22.6/F JSP JSS
Panel Mount
Junction Box
with Spade
Terminal Coil
6.1/F
10.1/F
10.6/F
11.6/F
JPSF JPST
9.1/F
17.1/F
22.6/F JPSP JPSS
Junction Box
with Screw
Terminal Coil
6.1/F
10.1/F
10.6/F
11.6/F
JKF JKH
9.1/F
17.1/F
22.6/F JKP JKB
Panel Mount
Junction Box
with Screw
Terminal Coil
6.1/F
10.1/F
10.6/F
11.6/F
JPKF JPKH
9.1/F
17.1/F
22.6/F JPKP JPKB
DIN
Connection
Solenoid
6.1/F
10.1/F
10.6/F
11.6/F
SC SU
9.1/F
17.1/F
22.6/F SD SV
Panel Mount
DIN Connection
Solenoid
6.1/F
10.1/F
10.6/F
11.6/F
OPSC OPSU
9.1/F
17.1/F
22.6/F OPSD OPSV

Important Note: One-piece molded epoxy Red-Hat II solenoids are a unique combination of coil and enclosure. When ordering some Red-Hat II options, it may be necessary to specify the appropriate catalog number prefixes for both the enclosure and the coil.

Type 1 General Purpose SoleoidsType 1 General Purpose Solenoids with Class F High Temperature Coils
Enclosures:
  • Also meet Type 2 Dripproof, Types 3 and 3S Raintight, and Types 4 and 4X Watertight requirements
  • Supplied standard with ½ threaded conduit hub and built-in strain relief for leads
Coils:
  • Insulation System suitable for coil temperatures up to 155°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: Supplied standard on all Red-Hat II Valves.
  Type 1 General Purpose SolenoidsType 1 General Purpose Solenoids with Class H High Temperature Coils
Enclosures:
  • Also meet Type 2 Dripproof, Types 3 and 3S Raintight, and Types 4 and 4X Watertight requirements
  • Supplied standard with ½ threaded conduit hub and built-in strain relief for leads
Coils:
  • Insulation System suitable for coil temperatures up to 180°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: Depending on wattage, use catalog number prefix "HT" or "HB" (e.g. HT8210G2) and specify voltage.

Type 1 Panel Mount SoleoidsPanel Mount Type 1 General Purpose Solenoids with Class F or Class H High Temperature Coils
Enclosures:
  • Panel mountable
  • Also meet Type 2 Drip proof, Types 3 and 3S Rain tight, and Types 4 and 4X Watertight requirements
  • Supplied standard with ½ threaded conduit hub and built-in strain relief for leads
Coils:
  • Same as Class F or Class H above
Ordering Information: For Class F coil, use catalog number prefix "GP" (e.g., GP8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "GPHT" or "GPHB" (e.g., GPHT8210G2) and specify voltage.
  Type 7 Explosionproof SolenoidsType 7 (A, B, C and D) Explosion proof Solenoids with Class F High Temperature Coils
Enclosures:
  • Also meet Types 3 and 3S Raintight, Types 4 and 4X Watertight, types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition proof requirements. Refer to Engineering Section.
  • Supplied standard with ½ threaded conduit hub and built-in strain relief for leads
Coils:
  • Insulation System suitable for coil temperatures up to 155°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: Use catalog number prefix "EF" (e.g. EF8210G2) and specify voltage.

Type 7 Explosionproof SolenoidsType 7 (A, B, C and D) Explosion proof Solenoids with Class H High Temperature Coils
Enclosures:
  • Also meet Types 3 and 3S Rain tight, Types 4 and 4X Watertight, types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition proof requirements. Refer to Engineering Section.
  • Supplied standard with ½ threaded conduit hub and built-in strain relief for leads
Coils:
  • Insulation System suitable for coil temperatures up to 180°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: Depending on wattage, use catalog number prefix "EFHT" or "EFHB" (e.g., EFHT8210G2) and specify voltage.
  Type 7 Explosionproof SolenoidsType 7 (A, B, C and D) Explosion proof Solenoids with Class F Coil only
Enclosures:
  • Also meet Types 3 and 3S Rain tight, Types 4 and 4X Watertight, types 6 and 6P Submersible and Type 9 (E, F and G) Dust Ignition proof requirements. Refer to Engineering Section.
  • Supplied with ½ 316 stainless steel threaded conduit hub, stainless steel base plate, and built-in strain relief for leads
Coils:
  • Insulation System suitable for coil temperatures up to 155°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: Use catalog number prefix "EV" (e.g. EV8210G2) and specify voltage.
Note: Not offered in any other class of insulation.

Open Frame SolenoidsOpen Frame Solenoids with Class F or Class H High Temperature Spade Terminal Coils
Valves with open frame solenoid construction are intended for use when a solenoid enclosure is not needed, e.g., mounting in a control cabinet.
Coils:
  • Insulation System suitable for coil temperatures up to 155°C² (for Class F) or up to 180°C² (for Class H) For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • ¼" spade terminals
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "OFSF" or "OFSP" (e.g., OFSF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "OFSS" or "OFST" (e.g., OFST8210G2) and specify voltage.
Note: Spade Terminal Coils are not available above 250 volts, AC or DC.
  Panel Mount SolenoidsPanel Mount Solenoids with Class F or Class H High Temperature Spade Terminal Coils
Coils:
  • Insulation System suitable for coil temperatures up to 155°C² (for Class F) or up to 180°C² (for Class H) For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Panel mountable with ¼" spade terminals
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "OPSF" or "OPSP" (e.g., OPSF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "OPSS" or "OPST" (e.g., OPST8210G2) and specify voltage.
Note: Spade Terminal Coils are not available above 250 volts, AC or DC.

Open Frame SolenoidsOpen Frame Solenoids with Class F or Class H High Temperature Screw Terminal Coils
Valves with open frame solenoid construction are intended for use when a solenoid enclosure is not needed, e.g., mounting in a control cabinet.
Coils:
  • Insulation System suitable for coil temperatures up to 155°C² (for Class F) or up to 180°C² (for Class H) For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • #8 screw terminals
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "OFKF" or "OFSKP" (e.g., OFKF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "OFKH" or "OFKB" (e.g., OFKH8210G2) and specify voltage.
  Panel Mount SolenoidsPanel Mount Solenoids with Class F or Class H High Temperature Screw Terminal Coils
Coils:
  • Insulation System suitable for coil temperatures up to 155°C² (for Class F) or up to 180°C² (for Class H) For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Panel mountable with #8 screw terminals
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "OPKF" or "OPKP" (e.g., OPKF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "OPKB" or "OPKH" (e.g., OPKH8210G2) and specify voltage.

Junction Box SolenoidsJunction Box Solenoids with Class F or Class H High Temperature Spade or Screw Terminal Coils
Enclosures:
  • Meet Type 1 General Purpose, Type 2 Dripp roof, Types 3 and 3S Rain tight, and Types 4 and 4X Watertight requirements
  • Supplied standard with ½ threaded conduit hub and grounding provision
Coils:
  • Insulation System suitable for coil temperatures up to 155°C² (for Class F) or up to 180°C² (for Class H) For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Must be ordered with either: #8 screw terminals or ¼" spade terminals
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "JSF", "JSP", "JKF" or "JKB" (e.g., JSF8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "JSS", "JST", "JKH" or "JKB" (e.g., JKH8210G2) and specify voltage.
  Junction Box SolenoidsJunction Box Solenoids for Class F or Class H Coils
Junction Box (shown installed on Red-Hat II solenoid) is a zinc coated steel housing with two 7/8" knockouts for through wiring. UL listed when ordered factory assembled. Also available, without UL listing, as a kit with grounding screw for field installation.

Ordering Information: For factory assembly, add prefix "JB" to Valve Catalog Number (e.g., JB8210G2).
For kit, use number 272140.

Din Connection SolenoidsClass F or Class H High Temperature Coils with DIN Connections
  • Meet ISO 4400/DIN 43650 requirements
  • Class F insulation system suitable for coil temperatures up to 155°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • Class H insulation system suitable for coil temperatures up to 180°C.² For ambient temperature requirements, refer to specific Series and charts in Engineering Section.
  • "Enclosure protection" with DIN connector equivalent of Types 1 and 4
  • Suitable for both 50 and 60 Hz ¹
Ordering Information: For Class F coil, depending on wattage, use catalog number prefix "SC" or "SD" (e.g., SC8210G2) and specify voltage.
For Class H coil, depending on wattage, use catalog number prefix "SU" or "SV" (e.g., SU8210G2) and specify voltage.
Note: Optional DIN-type strain-relief connector kit includes a gasket and mounting screw. Outlet accommodates cable with O.D. of 0.310" to 0.400". Must be ordered seperately as Kit No. 236034
   


Notes:
¹ Can be suplied for 50 Hz at a reduced voltage which is standard throughout the world, i.e., 120/60, 110/50.
² UL Limitations are 140°C for Class F insulation systems and 160°C for Class H insulation systems.

 

Back
Credit Cards Accepted by PSI

.

-© FLW, Inc 1997- - S.D.G.