2 WAY
Aluminum Body Solenoid Valves
Direct Acting and Pilot Operated - ³/8"
to 3" N.P.T.
    |
8040/8215
Series
 |
Specifications
Solenoid Enclosures: Valves listed in this series have either
Red-Hat metal solenoid enclosures or Red-Hat II molded epoxy solenoids.
Red-Hat II valves are identified by the change letter "G" in
their catalog numbers, e.g., 8040G10, and are shown in red.
Standard Enclosures:
Red-Hat -- Type 1 General Purpose
Red-Hat II -- Types 1, 2, 3, 3S, 4 and 4X Combination General Purpose
and Watertight
Optional Enclosures:
Red-Hat -- Types 3, 7 and 9 Combination Explosionproof and Raintight. To
order, add prefix "EF" to catalog number. (Except Catalog
Numbers EF8215A40, EF8215A90 and EF8215B93)²
Red-Hat II -- Types 3, 3S, 4, 4X, 6, 6P, 7 and 9 Combination
Explosionproof and Watertight. To order, add prefix "EF" to
catalog number.
Additional constructions are available. The Optional
Features Section contains descriptions and ordering information for:
Open Frame Solenoids · Junction Box Enclosures · Panel Mount
Constructions.
|
Electrical: Standard Voltages: 24, 120, 240, 480 volts, AC, 60 Hz
(or 110, 220 volts, AC, 50 Hz)
6, 12, 24, 120, 240 volts, DC
Other voltages are available when required.
Coil: Continuous duty molded Class B or F, as listed.
Nominal Ambient Temperature Ranges: Red-Hat and Red-Hat II
Valves/AC Construction: 32°F to 125°F.
Red-Hat Valves/DC Construction: 32°F to 77°F (104°F occasionally).
Red-Hat II Valves/DC Construction: 32°F to 104°F.
|
Valve Parts in Contact with Fluids:
Body -- Aluminum
Seals, Diaphragms and Discs -- Buna "N"
Disc Holder -- Nylon (10.1 and 11.6 watt Normally Open only)
Core Guide -- Acetal
Core Tube -- 305 Stainless Steel
Rider Rings -- Filled Teflon
Core and Plugnut -- 430F s.s., Silicone Steel (8215A40 and 8215A90)
Springs -- 302 s.s.
Shading Coil -- Copper
Approvals: CSA certified. UL listed as indicated. FM approved
(Normally Closed valves only, except Catalog Numbers 8215A90 and
8215A40). Meets applicable CE directives.
Ordering Information: Important: We must have catalog
number, voltage and Hertz, operating pressure and fluid handled. Use
strainers with Solenoid Valves. |
Pipe
Size
(ins.) |
Orifice
Size
(ins.) |
CV
Flow
Factor |
Operating
Pressure Differential
(psi) |
Max.
Fluid Temp.
°F |
Standard
Solenoid Enclosures
Red-Hat - Type 1
Red-Hat II - Types 1, 2, 3, 3S, 4 and 4X |
Watt
Rating/
Class of Coil
Insulation³ |
| Min. |
Max.
AC |
Max.
DC |
Aluminum
Body |
Air-
Fuel
Gas |
Air-
Fuel
Gas |
AC |
DC |
Catalog
Number |
Constr.
Ref.
No. |
UL
Listing |
AC |
DC |
| Normally
Closed (Closed when de-energized) |
| ¹/8 |
³/8 |
1.0 |
0 |
15 |
-- |
125 |
-- |
8040G6 |
11 |
o |
6.1/F |
-- |
| ¼ |
³/8 |
1.1 |
0 |
15 |
-- |
125 |
-- |
8040G7 |
11 |
o |
6.1/F |
-- |
| ³/8 |
³/8 |
1.2 |
0 |
15 |
-- |
125 |
-- |
8040G8 |
11 |
o |
6.1/F |
-- |
| ³/8 |
¾ |
3.4 |
0 |
50 |
25 |
125 |
104 |
8215G10 |
2 |
o |
10.1/F |
11.6/F |
| ³/8 |
¾ |
3.5 |
5 |
125 |
125 |
125 |
104 |
8215G1
¹ |
1 |
o |
6.1/F |
11.6/F |
| ½ |
¾ |
5.4 |
0 |
2 |
-- |
125 |
-- |
8040G22 |
13A |
o |
10.1/F |
-- |
| ½ |
¾ |
4.4 |
0 |
50 |
25 |
125 |
104 |
8215G20 |
2 |
o |
10.1/F |
11.6/F |
| ½ |
¾ |
4.8 |
5 |
125 |
125 |
125 |
104 |
8215G2
¹ |
1 |
o |
6.1/F |
11.6/F |
| ¾ |
¾ |
9.5 |
0 |
2 |
-- |
125 |
-- |
8040G23 |
13B |
o |
10.1/F |
-- |
| ¾ |
¾ |
5.1 |
0 |
50 |
25 |
125 |
104 |
8215G30 |
4 |
o |
10.1/F |
11.6/F |
| ¾ |
¾ |
5.1 |
5 |
125 |
125 |
125 |
104 |
8215G3
¹ |
3 |
o |
6.1/F |
11.6/F |
| 1 |
1
5/8 |
21 |
0 |
25 |
25 |
125 |
77 |
8215B50 4 |
6 |
o |
15.4/F |
14.9/F |
| 1
¼ |
1
5/8 |
32 |
0 |
25 |
25 |
125 |
77 |
8215B60 4 |
6 |
o |
15.4/F |
14.9/F |
| 1
½ |
1
5/8 |
35 |
0 |
25 |
25 |
125 |
77 |
8215B70 4 |
6 |
o |
15.4/F |
14.9/F |
| 2 |
2
3/32 |
60 |
0 |
25 |
15 |
125 |
77 |
8215B80 4 |
7 |
o |
15.4/F |
14.9/F |
| 2
½ |
3 |
117 |
0 |
5 |
-- |
125 |
-- |
8215A90 |
8 |
o |
28.2/F |
-- |
| 3 |
3 |
138 |
0 |
5 |
-- |
125 |
-- |
8215A40 |
8 |
o |
28.2/F |
-- |
| Normally Open
(Open when de-energized) |
| ³/8 |
¾ |
3.2 |
0 |
125 |
125 |
125 |
104 |
8215G13 |
9 |
· |
10.1/F |
11.6/F |
| ½ |
¾ |
4 |
0 |
125 |
125 |
125 |
104 |
8215G23 |
9 |
· |
10.1/F |
11.6/F |
| ¾ |
¾ |
4.6 |
0 |
125 |
125 |
125 |
104 |
8215G33 |
10 |
· |
10.1/F |
11.6/F |
| 1 |
1
5/8 |
22 |
0 |
25 |
15 |
125 |
77 |
8215C53 |
12 |
· |
15.4/F |
14.9/F |
| 1
¼ |
1
5/8 |
33 |
0 |
25 |
15 |
125 |
77 |
8215C63 |
12 |
· |
15.4/F |
14.9/F |
| 1
½ |
1
5/8 |
37 |
0 |
25 |
15 |
125 |
77 |
8215C73 |
13 |
· |
15.4/F |
14.9/F |
| 2 |
2
3/32 |
58 |
0 |
25 |
15 |
125 |
77 |
8215C83 |
14 |
· |
15.4/F |
14.9/F |
| 2
½ |
3 |
117 |
0 |
5 |
-- |
125 |
-- |
8215B93 |
15 |
· |
28.2/F |
-- |
| Notes: |
o - General
Purpose Valve - a normally open or normally closed valve intended to
control the flow of a fluid, but not to be depended upon to act as a
safety valve. This is a UL and CSA classification and is not intednded
to indicate valve service or application.
· - Safety Shutoff Valve -
a normally closed valve of the "on" and "off" type
inteded to be actuated by a safety control or emergency device to
prevent unsafe fluid delivery. It may also be used as a General Purpose
Valve. A mulitple port valve may be designated as a Safety Shutoff Valve
only with respect to its normally closed port. This is a UL, FM and CSA
valve classification.
|
1 - Do not use
for Fuel Gas.
2 - Suitable for Types 3 ad 7 (C and D) only, and have a T2B temperature
range code.
3 - On 50 Hertz service, the watt rating for the 6.1/F solenoid is 8.1
watts.
4 - FM Approved Process Control Valves (An FM Approved valve to control
flammable gas, but not to be relied upon as a safety shutoff valve.
Unless otherwise stated, valves are listed as General Purpose Valves.) |
|
|